PHL-SCDC REQUIERMENT |
AGREEMENT |
Yes |
No |
SPECIMEN ANALYSIS |
1 |
Negative pressure room with Adequate ventilation |
|
|
2 |
Certified Class II Biological Safety Cabinet (BSC) |
|
|
3 |
Positive pressure room with Adequate ventilation |
|
|
4 |
Availability of PPE including respirators (NIOSH certified N95) |
|
|
5 |
The seal/fitness test of disposable particulate respirator for Staff |
|
|
6 |
Training of staff for donning and doffing |
|
|
7 |
Physical security available 24/7 to cover all shifts |
|
|
8 |
All analyzers are maintained as per manufacturer instructions |
|
|
9 |
All lab General equipment are calibrated at least every six months |
|
|
10 |
Extraction and PCR Kits are validated and accepted for patient testing |
|
|
REPORTING OF RESULTS |
1 |
Use MOH HESN program for result reporting |
|
|
SPECIMEN STORAGE AND WASTE MANAGEMENT
|
1 |
Specimen must be stored in an appropriate condition before and after testing in secured area
|
|
|
2 |
Autoclave must be available and maintained |
|
|
3 |
Disinfectants solutions and biological spill kit must be available and efficient |
|
|
LABORATORY CAPACITY |
1 |
The laboratory has two Nucleic Acid extraction Systems |
|
|
|
2 |
The laboratory has two Real-Time PCR Systems |
|
|
|
3 |
The laboratory has at least 5 licensed Clinical Laboratory Technologists with experience in Molecular Biology and are BICSL Certified |
|
|
4 |
The laboratory has at least one consultant Microbiologist with experience in Molecular Biology |
|
|
Attachments |
BSC Calibration Certificate |
SCFHS for Consultant Microbiologist please scan all the 5 licenses in 1 PDF |